Gdjz-50kv 70kv digital AC DC output high voltage withstand voltage test oil transformer withstand voltage tester

GDJZ-50KV 70KV Digital AC DC Output High Voltage Withstand Test Oil Type Transformer Hipot TesterIntroduction:GDJ Series Oil Immersed Test Transformer AC DC Hipot Tester for Cable Withstand Voltage Testing is applied in power system for insulation test of high voltage equipment.The typical application of the HIPOT tester is

Featured Products

GDJZ-50KV 70KV Digital AC DC Output High Voltage Withstand Test Oil Type Transformer Hipot Tester

Gdjz-50kv 70kv Digital AC DC Output High Voltage Withstand Test Oil Type Transformer Hipot Tester
Gdjz-50kv 70kv Digital AC DC Output High Voltage Withstand Test Oil Type Transformer Hipot Tester

Introduction:

GDJ Series Oil Immersed Test Transformer AC DC Hipot Tester for Cable Withstand Voltage Testing is applied in power system for insulation test of high voltage equipment.

The typical application of the HIPOT tester is as follow:

  • Power Transformer AC high voltage withstand test

  • Circuit Breaker AC high voltage withstand test

  • High voltage motors high voltage withstand test

  • Voltage/current transformer high voltage withstand test

  • High voltage power source for calibration of high voltage meter

 

Model Selection Table:

  • Please confirm the right model before order. The main parameters include input voltage, maximum output voltage and capacity.

  • The parameters in this table are response for HV transformer only and we will install the main control box according to the capacity and input voltage of the model you order.

Capacity

KVA

GDJZ-50 Series

GDJZ-100 Series

GDJZ-150 Series

AC

DC

AC

DC

AC

DC

3kVA

50KV

70KV

    

5kVA

50KV

70KV

100KV

140KV

  

10kVA

50KV

70KV

100KV

140KV

150kV

210KV

15kVA

50KV

70KV

100KV

140KV

150kV

210KV

20kVA

50KV

70KV

100KV

140KV

150kV

210KV

25kVA

50KV

70KV

100KV

140KV

150kV

210KV

30kVA

50KV

70KV

100KV

140KV

150kV

210KV

50kVA

50KV

70KV

100KV

140KV

150kV

210KV

 

Notice:

  • If the maximum voltage is less than 100kv we will offer dry HV transformer for the tester, otherwise we will offer oil HV transformer for the tester;

  • The capacity and maximum voltage output could be customized according to the requirements of customer if you can not find the right one in this table;

  • The weight listed in the table is HV transformer only it does not include the weight of main control box. Please confirm the total weight of the tester with our sales engineer before order;


Customer Visiting

Gdjz-50kv 70kv Digital AC DC Output High Voltage Withstand Test Oil Type Transformer Hipot Tester
 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours